Spark & Co Logo

MICROFLOW

High precision flow targeting technology in a robust, production-ready system MICROLFOW will match Low to High flow requirements.
Add to Quote
Add to Quote
Specifications details Specifications Features

MACHINE SPECIFICATIONS

Loading height from floor 1050mm (41.50“)102” (2590 mm)
Overall size760mm (30“) W x 2030mm (80“) L x 2160mm (85“) H
Weightapprox. 1250 kg

TESTING CAPACITY (STANDARD RANGE)

Maximum test pressure 14 MPa
Minimum test pressure 10 MPa (NOTE: At pressures <10 MPa flow correlation may diminish)
Pressure control±0.1%
Calibration fluid temperature range20–40 °C controlled to ±1.5 °C

AVAILABLE FLOW RANGES FOR OPTIMUM PERFORMANCE

flow rate rangemaximum error
Option 110–275 gram /min.±0.19–±0.10%
Option 2200–2500 gram/min.±0.13–±0.10%
Option 3850–8500 gram/min.±0.14–±0.10%

FLOW TEST FLUID SUPPLY

Fluid tank40 liter reservoir with flooded suction pumps.
Motors 5 hp (3,7 kW) motor for test fluid pressure supply. 1 hp (0,8 kW) motor for clamping and hydraulic circulation.
IndicatorsHigh pressure – 3 μm canister type with dirty filter indicator.
FiltrationLow pressure – 1 μm canister type with dirty filter indicator.
NoiseMaximum working noise level is 75 dBA.
LocationInside machine base.
CoolingA water-/oil-type heat exchanger sized to remove required heat at maximum ambient temperature of 40 °C.
FittingsStraight-thread, o-ring, seal-type SAE J1926-1 (ISO 11926-1).

Electrical

Input power 200–480 VAC, 3 Phase, 50/60 Hz
Input current 50/25 A depending on input voltage

CONTROLS

Programmable Logic Controller (PLC) Allen Bradley/Siemens
Software Allen Bradley/Siemens
Human Machine Interface (HMI) 10” industrial touch screen
Remote connectivity Fast ethernet switch enables remote access to PLC and HMI.
Data collection Production data logging and process data filing.

DESCRIPTION

Simple cell, Duplex, Multiple functions, customized… High precision flow targeting technology in a robust, production-ready system MICROLFOW will match Low to High flow requirements. This new MICROFLOW TEST design is the result of decades of fuel system processing experience on large scale automated systems. The new MICROFLOW TEST brings the same precision processing of a fully automated measure system, now packed into a smaller package as a stand alone machine. The small scale robust design is scalable to your production requirements and delivers a combination of high precision, reliability, accuracy, and ease of use.

 

 

 